TXN Inverter Series
------------------------------------------------------------------------------------------
| TXN Series single phase Inverter
Technical Index |
| |
| Model |
TXN2000 |
TXN3000 |
TXN5000 |
TXN6000 |
TXN10000 |
TXN15000 |
TXN20000 |
TXN30000 |
| Power out VA/W |
2000VA/1.6KW |
3000VA/2.4KW |
5000VA/4KW |
6000VA/4.8KW |
10000VA/8KW |
15000VA/12KW |
20000VA/16KW |
30000VA/24KW |
| Input |
DC input |
Rated
220VAC(180V-270V) or rated 110VDC90V-150V) optional
with anti-surgge and noise restraining circuit |
| Output features |
voltage and waveform |
220V1%
pure sine wave |
| Frequency stability |
50Hz0.5% |
| Voltage stability |
The
loading increases from 0 to 100%, the output difference
is 2% |
| Distortion |
When
loading <3% |
| Over load capacity |
Running
correctly in 120%, running for 25s in 150% |
| Output isolation |
Transformer
isolation output |
| Short circuit protection |
Automatically
recover |
| Wave crest factor |
Better
than 31 |
| Efficiency |
DC
TO
AC |
81% |
82% |
83% |
84% |
86% |
90% |
| LCD
display |
The
parameter display with back light: status dispaly, displaying
model, voltage in, voltage out, frequency, loading,
working temperature and DC voltage etc. |
| Voice alarming |
DC failure |
Low
DC input, alarming once per second, continuous alarming
in case of DC failure |
| UPS failure |
continuous
alarming |
| Others |
Communication access |
RS-232
DB9 access, monitoring the status and paramneter on
computer; the machine can send automatic calling and
mobile phone information. |
| Safety standard |
EN500911/2IEC950 |
| Monitoring software |
UPSilon2000 |
| Noise |
less
than 55 db in 1 m. |
| Operative temperature |
0桫40 |
| Relative humidity |
10%90%
no coagulation |
| Working height |
Below
5000 feet |
| Dimension (WDH) |
260495660 |
260615675 |
3807901090 |
3807901350 |
| Weight(kg) |
76 |
91 |
105 |
119 |
167 |
228 |
261 |
335 |
|
| |
| TXN Series Single
Phase Inverter Technical Index |
| Model |
TXN-10KVA |
TXN-15KVA |
TXN-20KVA |
TXN-30KVA |
TXN-40KVA |
TXN-50KVA |
TXN-60KVA |
TXN-80KVA |
TXN-90KVA |
TXN-100KVA |
| Capacity |
VA/W |
10KVA/8KW |
15KVA/12KW |
20KVA/16KW |
30KVA/24KW |
40KVA/32KW |
50KVA/40KW |
60KVA/48KW |
80KVA/60KW |
90KVA/67.5KW |
100KVA/75KW |
| Input |
Voltage range |
Rated
220VAC(180V-270V) or rated 110VDC90V-150V) optional
with anti-surgge and noise restraining circuit |
| Output |
Voltage |
220VAC1%380VAC1% |
| Voltage stability |
static
1% |
| dynamic
difference 2%, the loading increases from 0 to 100% |
| Frequency |
50Hz0.5% |
| Distortion |
Under
full loading <3%(THD) |
| Over load capacity |
150%
30s |
| Wave crest factor |
Better
than 31 |
| waveform |
sine
wave |
| Efficiency |
DC TO AC |
86% |
90% |
92% |
| LCD display |
The parameter display with back light |
status
dispaly, displaying model, voltage in, voltage out,
frequency, loading, working temperature and DC voltage
etc. |
| LED display |
Working status display |
Display
the working procedure status |
| Voice alarming |
Low DC voltage |
Once
per second |
| inverter failure |
continuous
alarming |
| Others |
Communication access |
RS232
DB9 |
| Safety standard |
EN500911/2IEC950 |
| Monitoring software |
UPSilon2000 |
| Noise |
less
than 50 db in 3 m. |
| Operative temperature |
-10桫40 |
| Relative humidity |
10%90%
no coagulation |
| Working height |
Below
5000 feet |
| Dimension (WDH) |
6507001540 |
6508001690 |
13008001690 |
| Net weight (kg) |
220 |
320 |
360 |
400 |
480 |
520 |
550 |
780 |
850 |
950 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|